Place of Origin:
China (Mainland)
Nama merek:
Kacise
Sertifikasi:
certificate of explosion-proof,
Model Number:
M18 KUS1000
KUS series ultrasonic transmitter
Unit in the diagram is mm.
General specifications
M18 | |
Sensing range | 100... 1000 mm |
Adjustment range | 100….1000mm |
Unusable area | 0 ... 100 mm |
Standard target plate | 100 mm x 100 mm |
Transducer frequency | approx.220 kHz |
Response delay | approx. 10 ms |
M30-type1 | |
Sensing range | 200... 2000 mm |
Adjustment range | 200….2000mm |
Unusable area | 0 ... 200 mm |
Standard target plate | 100 mm x 100 mm |
Transducer frequency | approx.150 kHz |
Response delay | approx. 10 ms |
M30-type2 | |
Sensing range | 200... 3000 mm |
Adjustment range | 200….3000mm |
Unusable area | 0 ... 150 mm |
Standard target plate | 100 mm x 100 mm |
Transducer frequency | approx.70 kHz |
Response delay | approx. 20 ms |
M30-type3 | |
Sensing range | 400... 6000 mm |
Adjustment range | 400….6000mm |
Unusable area | 0 ... 300 mm |
Standard target plate | 100 mm x 100 mm |
Transducer frequency | approx.70 kHz |
Response delay | approx. 40 ms |
Indicators/operating means
LED blue |
Flashing :program can be acted, this status The Blue led will flash around 5 minute after the sensor power on, indicate the sensor can be programed, and then the blue led will perpetually turn on. To indicate the power status. |
LED yellow |
indication of the switching state flashing: during program function object detected |
LED red |
Normal working: light on indicate error detected. Programing: flashing, echo lost, that means the sensor covered or no object in the fromt of the sensor, |
Electrical specifications
Operating voltage UB | 13 ... 30 V DC , ripple 10 %SS |
No-load supply current I0 | ≤ 45 mA |
Input
Input type | 1 TEACH-IN input |
operating range A1: 0V/GND ... +1 V, operating range A2: +6 V ... +UB |
|
input impedance: > 4.7 kΩ ; TEACH-IN program pulse: ≥ 1 s |
Output
Output type |
1 switch output E4, NPN NO/NC, programmable 2 switch output E4, PNP NO/NC, programmable 3 Analog 0-10V output E4 programmable. 4 Analog 4-20mA output E4 programmable 5 RS485 output E4 programmable. |
Rated operating current Ie | 200 mA , short-circuit/overload protected |
Default setting | Switching point A1:150mm Switching point A2: 1000mm |
Voltage drop | ≤ 2.5 V |
Repeat accuracy | ≤1 % |
Switching frequency f | ≤ 13 Hz(customized for high frequency version) |
Range hysteresis H | 5 % of the set operating distance |
Temperature influence | ±1.5% of full-scale value |
Ambient conditions
Ambient temperature | -25…70℃(248...343K) |
Storage temperature | -40…85℃(233...358K) |
Mechanical specifications
Connection | V1 connector(M12×1),4-pin |
Protection degree | IP67 |
Material Housing | brass, nickel-plated |
Transducer |
epoxy resin/hollow glass sphere mixture; foam polyurethane, cover PBT |
Adjusting the switching points and the analog output.
The switch output type and analog output type sensor can be programed as the user want.
There is 8 types of output functions can be programed.
All the teach routine as follows,
step 1 teach one point with the related teach in condition(High level voltage or GND). step 2 choose a different distance(not the same with step1) point and a different teach in condition(not same with the step1). The program routine must be finished during the blue led flashing, the default value will be efficient if the not.
The ultrasonic sensor features a switch output with two teachable switching points. These are set by applying the supply voltage - UB or + UB to the TEACH-IN input. The supply voltage must be applied to the TEACH-IN input for at least 1 s. LEDs indicate whether the sensor has recognized the target during the TEACH-IN procedure. Switching point A1 is taught with - UB, A2 with +UB. Five different output functions can be set.
1. Window mode normally-open and liner mode positive slope output function.
2. Window mode normally-closed and liner mode negative slope output function.
3. Single switching point, normally-open function.
4. Single switching point, normally-closed function.
5. Single switch point with hysteresis gap normally-open function.
6. Single switch point with hysteresis gap normally-closed function.
7. Detection of object presence-normal open function.
8. Detection of object presence-closed open function.
Switching point, Setting distance only after power on. The internal clock can assure can't be changed after 5 minutes after power on. If want to change the switching point, the user can only setting the request distance after power restart.
For the RS485 output type.
There is 2 kinds of working style,
One for auto measure, the sensor will measure the distance or level repeatedly, ant the measurement period can be set by the uart. The measure result can be fetched every time.
The other style is power save mode when the sensor is sleep, until the sensor received the inquiry command with pre-code. Communication protocol is Modus-RTU.
For example the measure result can be read by access the register 0x101 by Modbus protocol.
For more information please contact us for the software engineering guide.
LED displays | |||
Programming time | Working time | ||
Red LED | ON | -- | Error accured |
OFF | Working well | Working well | |
Flash |
Doing the echo lost program, For Single switching point, program, or Detection of object. |
----- | |
Yellow LED | ON | ---- | Object detacted |
OFF | ------ | Echo lost | |
Flash |
Teach in for the status ready, That means the sensor has locked the set distance for program |
----- | |
Blue LED | ON | Power on | Power on |
OFF | Power off | Power off | |
Flash |
Program period indication, Only the blue led flashes the program routine can be done |
Program can be carried on |
5. Installation conditions
If the sensor is installed at the environment temperature fall below 0℃,It should do well on the protective measures. In case of direct mounting of the sensor in a through hole using the steel nuts, it has to be fixed at the middle of the housing thread.
GXUS | Body size | OUTPUT | Max range | Description | |
M18 | For M18 body, The max range for M18 is 1000mm | ||||
M30-Type1 | For M30 body. The max range is 2000mm for M30 | ||||
M30-Type2 | For M30 body. The max range is 3000mm for M30 | ||||
M30-Type3 | For M30 body. The max range is 6000mm for M30 | ||||
Customized | Customized | ||||
NPN | Output is NPN | ||||
PNP | Output is PNP | ||||
Vout | Output is Vout 0-10V | ||||
mAout | Output is 4-20mA | ||||
RS485 | Output is RS485 | ||||
XXX mm |
Xxx mm is the maxim range can be detected For M18 the max range is 1000mm For M30 the max range is 6000mm |
||||
GXUS | M30 | RS485 | 2000mm |
Kirim pertanyaan Anda langsung ke kami