SC4AJ Conductivity Sensor with Cell Constants 0.02 cm-1 and 0.1 cm-1 for Temperature Range 0 to 110℃

SC4AJ Conductivity Sensor with Cell Constants 0.02 cm-1 and 0.1 cm-1 for Temperature Range 0 to 110℃

Cell constant 0.02 cm-1 Conductivity Sensor

Cell constant 0.1 cm-1 SC4AJ

Temperature Range 0 to 110℃ Water Quality Sensor

Nama merek:

Yokogawa

Nomor model:

Sensor SC4AJ

Hubungi Kami
Minta Kutipan
Rincian produk
Prinsip pengukuran:
Sistem dua elektroda
Konstan sel:
0,02 cm-1, 0,1cm-1
Kisaran suhu:
0 hingga 110 ℃ (untuk elektroda)
Sterilisasi untuk elektroda:
135 ℃ (275 ℉), dalam waktu 30 menit dalam sterilisasi uap
Rentang tekanan:
0 hingga 1 MPa (untuk elektroda)
Menyoroti:

Cell constant 0.02 cm-1 Conductivity Sensor

,

Cell constant 0.1 cm-1 SC4AJ

,

Temperature Range 0 to 110℃ Water Quality Sensor

Syarat Pembayaran & Pengiriman
Kuantitas min Order
1 pcs
Kemasan rincian
Setiap unit memiliki kotak individual dan semua kotak dikemas dalam paket standar atau permintaan pe
Waktu pengiriman
5-8 hari kerja
Syarat-syarat pembayaran
MoneyGram, Western Union, T/T, D/P, D/A, L/C.
Menyediakan kemampuan
1000 karya/potong per minggu yang bisa dinegosiasikan
Deskripsi Produk
Conductivity Sensor SC4AJ
Yokogawa has been supplying superior on-line analyzers for monitoring or controlling the conductivity of liquid solutions. Our product line includes the FLXA402 four-wire conductivity/resistivity converter, along with the FLXA202 and FLXA21 two-wire conductivity/resistivity transmitters, complemented by a range of precision sensors for accurate liquid conductivity measurement.
The SC4AJ conductivity sensor features a compact, convenient design suitable for diverse applications including boiler water monitoring, hydroponics conductivity measurement, and ultrapure water resistivity measurement in semiconductor, pharmaceutical, food, and power industries.
Specifications
Measurement Object Conductivity of liquids or solutions
Measuring Principle Two-electrode system
Cell Constant 0.02 cm-1, 0.1 cm-1
Measuring Range
  • 0 - 0.5 to 0 - 200 μS/cm (Cell constant: 0.02 cm-1, with SC450G, SC202)
  • 0 - 100 μS/cm to 0 - 1 mS/cm (Cell constant: 0.02 cm-1, with SC100)
  • 0 - 5 μS/cm to 0 - 1 mS/cm (Cell constant: 0.1 cm-1, with SC450G, SC202)
  • 0 - 500 μS/cm to 0 - 5 mS/cm (Cell constant: 0.1 cm-1, with SC100; Material: Titanium)
Temperature Range 0 to 110℃ (For electrode)
Sterilization for Electrode 135℃ (275℉), within 30 minutes in Steam Sterilization
Pressure Range 0 to 1 MPa (For electrode)
Sample Solution Condition Although flow rate is not limited in measurement, air bubbles should not be mixed in the sample solutions to obtain correct measured values.
Temperature Sensor Pt1000
Weight Sensors:
  • Adapter mounting type (SC4AJ-S-AD-09-002-05): approx. 450 g
  • Adapter mounting type (SC4AJ-S-AD-15-002-05): approx. 520 g
  • Welding socket type (SC4AJ-S-SA-NN-002-05): approx. 670 g
  • 5" welding clamp type (SC4AJ-S-SB-NN-002-05): approx. 550 g
  • 2" welding clamp type (SC4AJ-S-SC-NN-002-05): approx. 670 g
Adapters:
  • 3/4" stainless steel adapter (/PS): approx. 110 g
  • 3/4" PVDF adapter (/PF): approx. 35 g
  • Straight welding socket (/SA1): approx. 300 g
  • Angle welding socket 15 (/SA2): approx. 320 g
  • Welding clamp 1" (/SB1): approx. 330 g
  • Welding clamp 1.5" (/SB2): approx. 305 g
  • Welding clamp 2" (/SC1): approx. 350 g
Process Connection Adapter mounting, welding socket, welding clamp